Summary of Product Characteristics (SmPC) - RADELUMIN 2000 MBQ/ML SOLUTION FOR INJECTION
1 NAME OF THE MEDICINAL PRODUCT
Radelumin 2000 MBq/mL solution for injection
2 QUALITATIVE AND QUANTITATIVE COMPOSITION
Each mL of solution contains 2000 MBq [18F]PSMA-1007 at the activity reference time (ART).
One 10 mL vial contains 0.3 to 10 mL of solution, corresponding to 600-20000 MBq at activity reference time (ART).
One 15 mL vial contains 0.3 to 15 mL of solution, corresponding to 600-30000 MBq at activity reference time (ART).
One 20 mL vial contains 0.3 to 20 mL of solution, corresponding to 600-40000 MBq at activity reference time (ART).
Fluorine (18F) decays to stable oxygen (18O) with a half-life of 110 minutes by emitting a positron radiation of maximum energy of 634 keV, followed by positron annihilation radiation of 511 keV.
Excipients with known effect
Each mL of solution contains up to 5 mg of sodium, up to 0.1 mg of potassium and up to 80 mg ethanol.
For full list of excipients, see section 6.1.
3 PHARMACEUTICAL FORM
Solution for injection.
Clear, colourless or slightly yellow solution, free from visible particles, with a pH value between 4.5 and 8.5.
4 CLINICAL PARTICULARS
4.1 Therapeutic indications
This medicinal product is for diagnostic use only.
Radelumin is indicated for the detection of prostate-specific membrane antigen (PSMA)-positive lesions with positron emission tomography (PET) in adults with prostate cancer (PCa) in the following clinical settings:
- Primary staging of patients with high-risk PCa prior to primary curative therapy,
- Suspected PCa recurrence in patients with increasing levels of serum prostate-specific antigen (PSA) after primary curative therapy.
4.2 Posology and method of administration
Radelumin should be administered by appropriately qualified healthcare professionals and only in a designated nuclear medicine facility.
Posology
Adults
The recommended activity of [18F]PSMA-1007 for an adult is 3.6-4.4 MBq/kg body mass ( i.e. 252-308 MBq for a 70 kg patient), according to the type of camera used and acquisition mode.
The maximum activity injected should not exceed 450 MBq.
The maximum volume of solution for injection should not exceed 10 mL.
Elderly
No dose adjustment required.
Renal impairment
Radelumin has not been studied in patients with renal impairment.
No dose adjustment is considered necessary in patients with renal impairment (see section 5.2).
Hepatic impairment
Radelumin has not been studied in patients with hepatic impairment.
No dose adjustment is considered necessary in patients with hepatic impairment (see section 5.2).
Pediatric population
There is no relevant use of [18F]PSMA-1007 in the pediatric population.
Method of administration
For intravenous use.
The activity of [18F]PSMA-1007 has to be measured with an activimeter immediately prior to injection.
The recommended maximum volume of injection of Radelumin is 10 mL.
For instructions on dilution of the medicinal product before administration, see section 12.
Image acquisition
The patient should be positioned in supine, with arms above the head, if feasible. A CT or MRI scan should be obtained for attenuation correction and anatomic correlation. The PET scanning should begin 90 minutes to 120 minutes after completion of the injection. It is recommended that acquisition should start from mid-thigh and proceed to skull vertex.
4.3 Contraindications
Hypersensitivity to the active substance or to any of the excipients listed in section 6.1.
4.4 Special warnings and precautions for use
Individual benefit/risk justification
For each patient, the radiation exposure must be justifiable by the likely benefit. The activity administered should in every case be as low as reasonably achievable to obtain the required diagnostic information.
To date no outcome data exist to inform subsequent management of patients with high-risk disease when PSMA PET/CT is utilised for primary staging.
Interpretation of [18F]PSMA-1007 images
[18F]PSMA-1007 images should be interpreted by appropriately trained nuclear medicine specialists trained in [18F]PSMA-1007 PET.
PET images with [18F]PSMA-1007 should be interpreted visually. Suspicion of cancerous tissue in sites typical for prostate cancer recurrence is based on [18F]PSMA-1007 uptake at these sites relative to that of the background and side-by-side evaluation of information from corresponding CT and/or MRI. Typical patterns of known physiological uptake of PSMA-targeting tracers should be taken into consideration.
The detection of prostate cancer recurrence in prostate/prostate bed, regional lymph nodes, non-regional lymph nodes, bone, soft tissue and visceral organs by [18F]PSMA-1007 has been reported.
The impact of quantitative/semiquantitative measurement of [18F]PSMA-1007 uptake as an aid to image interpretation has not been assessed.
Image interpretation errors can occur with PET with [18F]PSMA-1007.
[18F]PSMA-1007 uptake is not specific to prostate cancer and may occur in normal tissues (see section 5.2), with other types of cancer and non-malignant processes, potentially leading to false positive findings. Moderate to high physiological PSMA uptake is noted in the kidneys, lacrimal glands, liver, salivary glands, gallbladder, spleen and pancreas. False positive findings include, but are not limited to, other types of cancer (e.g. renal cell carcinoma, hepatocellular carcinoma, breast cancer), benign bone diseases (e.g. Paget’s disease), inflammatory processes in activated lymph nodes, benign thyroid diseases, liver inflammation, prostatitis, benign prostatic hyperplasia, gliomas and healing rib fractures. Ganglia can mimic lymph nodes. Focal unspecific bone uptake has been reported to occur in some cases with [18F]PSMA-1007 without morphological correlate on CT predominantly in the ribs. Careful consideration of the patient’s disease history, other laboratory results and check for CT correlates should be applied in cases of unspecific bone uptake in order to evaluate the presence of potential bone metastases.
The diagnostic performance of [18F]PSMA-1007 may be affected by serum PSA levels, androgen-receptor-targeting treatments, disease stage and size of malignant lymph nodes (see section 5.1). Lesions smaller than 4 mm may be missed due to the limited spatial resolution of PET/CT.
Further investigation, which may include histopathological evaluation of the suspected lesions, should be considered where appropriate.
After the procedure
Close contact with infants and pregnant women should be restricted during the initial 12 hours following the injection.
Specific warnings
This medicine contains up to 50 mg sodium per injected activity (10 mL), equivalent to 2.5% of the WHO recommended maximum daily intake of 2 g sodium for an adult. To be taken into consideration for patients who are on a controlled sodium diet.
This medicine contains up to 1 mg potassium per injected activity (10 mL), which is less than 1 mmol per dose, i.e. essentially potassium-free‘.
This medicine contains up to 800 mg ethanol per injected activity (8% w/v). This amount in 10 mL of this medicine is equivalent to ≤ 20 mL of beer or ≤ 8 mL of wine. To be taken into consideration for patients with known alcohol dependency.
4.5 Interaction with other medicinal products and other forms of interaction
No interaction studies have been performed.
4.6 Fertility, pregnancy and lactation
Pregnancy and lactation
Radelumin is not indicated for use in women.
Fertility
No studies on fertility have been performed.
4.7 Effects on ability to drive and use machines
Radelumin contains a very small amount of alcohol which may reduce the ability to drive and operate machinery in some sensitive individuals.
4.8 Undesirable effects
The safety profile of [18F]PSMA-1007 was evaluated in 191 patients with suspected biochemical recurrent prostate cancer (ABX-CT-301 study), and from more than 1000 patients published in the literature.
No undesirable effects have been reported to date.
Exposure to ionising radiation is linked with cancer induction and a potential for development of hereditary defects. As the effective dose is 8.6 mSv when the maximum recommended activity of 450 MBq of [18F]PSMA-1007 is administered, these adverse reactions are expected to occur with a low probability.
Reporting of suspected adverse reactions
Reporting suspected adverse reactions after authorisation of the medicinal product is important. It allows continued monitoring of the benefit/risk balance of the medicinal product. Healthcare professionals are asked to report any suspected adverse reactions via the Yellow Card Scheme:
Website: www.mhra.gov.uk/yellowcard or search for MHRA Yellow Card in the Google Play or Apple App Store.
4.9 Overdose
In the event of administration of a radiation overdose with [18F]PSMA-1007, the nuclear medicine specialist in charge of the examination should take the necessary measures to ensure that the patient's radiation exposure is maintained at a value generally accepted for diagnostic nuclear medicine or radiology examinations. These measures will vary from patient to patient depending on the clinical condition and the extent of the overdose and may be limited to simple monitoring. It might be helpful to estimate the effective dose that was applied.
5 PHARMACOLOGICAL PROPERTIES
5.1 Pharmacodynamic properties
Pharmacotherapeutic group: Other diagnostic radiopharmaceuticals for tumour detection, ATC code: V09IX17
Mechanism of action
[18F]PSMA-1007 is a synthetic peptidomimetic which contains the prostate-specific membrane antigen (PSMA) pharmacophor Glu-NH-CO-NH-Lys. It binds with high affinity to the PSMA enzymatic site, which is over-expressed in most prostate cancer cells and is internalised after binding. Due to internalization, enhanced accumulation of [18F]PSMA-1007 in prostate cancer cells occurs.
Pharmacodynamic effects
At the molar concentrations corresponding to the recommended activities, [18F]PSMA-1007 does not appear to have any pharmacodynamic activity.
Clinical efficacy and safety
Primary staging
In the prospective study by Hermsen et al. (Eur J Nucl Med Mol Imaging. 2022; 49(11): 3929-3937), 99 adult male patients (mean age 68.1 ± 6.6 years) with biopsy proven PCa of intermediate (35/99) and high-risk disease (64/99) indicated for extended pelvic lymph node dissection (ePLND) underwent [18F]PSMA-1007 PET/CT. PET/CT scans were evaluated by two independent readers and ePLND served as the histopathology reference standard. The patient-based sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of [18F]PSMA-1007 PET/CT imaging to detect lymph node metastasis is shown in Table
- 1. Lymph nodes not detected in PET/CT, but invaded by PCa at histopathology had a mean diameter of 3.5 mm (95% CI 3.0-4.1 mm).
In the retrospective study by Sprute et al. (J Nucl Med. 2021; 62(2):208-213), 96 adult male patients (mean age 69.5) underwent [18F]PSMA-1007 PET/CT for staging (87/96) or recurrence (9/96), followed by ePLND or salvage lymphadectomy. PET/CT image analysis and their histopathologic correlation were evaluated by each individual centre, in case of discordance, a consensus read by two nuclear medicine physicians at Heidelberg University Hospital was done. Subgroup analyses were performed for different lymph node sizes (all sizes, lymph nodes > 3mm). The patient-based and lesion-based sensitivity, specificity, PPV and NPV of [18F]PSMA-1007 PET/CT imaging to detect lymph node metastasis is shown in Table 1.
Table 1: diagnostic performance of [18F]PSMA-1007 PET/CT for detection of lymph node metastasis in primary staging in patients with biopsy proven prostate cancer
Patient-based N=99 (Hermsen et al.) | Lesion-based N=1746 dissected lymph nodes (Sprute et al.) | Lesion-based (lymph nodes >3 mm) N=1746 dissected lymph nodes (Sprute et al.) | Patient-based N=96 (Sprute et al.) | Patient- | |||
| based | |||||||
| (lymph | |||||||
| nodes | |||||||
| >3mm) | |||||||
| N=96 | |||||||
| (Sprute et | |||||||
| al.) | |||||||
| Sensitivity (95% CI) | 53.3 % (34.4-71.7 %) | 71.2 % | 81.7 % | 50.0 % | 64.3 % | ||
| Specificity (95% CI) | 89.9 % (80.2-95.8 %) | 99.5 % | 99.6 % | 89.7 % | 91.2 % | ||
| PPV (95% CI) | 69.6 % (51.2-83.3 %) | 91.3 % | 92.4 % | 66.7 % | 75.0 % | ||
| NPV (95% CI) | 81.6 % (75.0-86.8 %) | 97.9 % | 98.9 % | 81.3 % | 86.1 % | ||
Suspected PCa recurrence The pivotal efficacy data is derived from 190 patients evaluated in the randomised, open-label, cross-over ABX-CT-301 study at six different centers in France. Patients were adult and elderly men (mean age 68.7 years, range 49-84) presenting with suspected recurrence of prostate cancer, based on elevated serum PSA levels after initial curative treatment for localised prostate cancer (main curative treatments were prostatectomy with pelvic lymph node dissection (48.7%), prostatectomy (32.8%), and radiation (including external beam radiation and brachytherapy) with or without hormone therapy (16.4%)). The study was an active comparator study: PET/CT with [18F]PSMA-1007 was compared to PET/CT with fluorocholine (18F).
PET/CT images obtained from each patient with the two radiopharmaceuticals were interpreted by three independent blinded readers, and the observed results compared to a composite standard of truth (cSOT), with the extent of disease determined by an expert panel blinded to both PET/CT scans.
The diagnostic performance of [18F]PSMA-1007 and fluorocholine (18F) PET/CT was characterised as detection rate (agreement of the positive read results with the cSOT) and is shown in Table 2. The mean detection rate across all readers was 77% for [18F]PSMA-1007 and 57% for fluorocholine (18F), the difference was statistically significant (odds ratio 2.61; 95% confidence interval 1.97-3.45); p<0.0001). Detection rates stratified by serum PSA levels are also shown in Table 2.
Table 2: detection rate of prostate cancer lesions, blinded read with cSOT as reference, patient level
| N | [18F]PSMA-1007 | Fluorocholine (18F) | Odds Ratio | ||||
| [18F]PSMA-1007/ | |||||||
| Fluorocholine | |||||||
| (18F) | |||||||
| (95% CI) | |||||||
| Detection rate overall | 179 | 77.0 % | 56.5 % | 2.61 (1.97-3.45) | |||
| Detection rate by serum PSA level | |||||||
| PSA < 0.5 ng/mL | 43 | 56.6 % | 38.8 % | 2.10 (1.13-3.89) | |||
| 0.5 <= PSA < 1.0 ng/mL | 25 | 82.7 % | 42.7 % | 6.88 (3.35-14.13) | |||
| 1.0 <= PSA < 2.0 ng/mL | 33 | 80.8 % |
| 4.31 (2.26-8.24) | |||
| PSA >= 2.0 ng/mL | 78 | 84.6 % | 73.5 % | 2.01 (1.27-3.19) | |||
In the region-based analysis, there were 78 regions from 72 patients with cSOT-confirmed prostate cancer lesions. The most commonly affected regions were pelvis (n=59, including prostate lodge, pelvic lymph nodes and pelvic skeleton), followed by spine (n=6). Other regions were affected in 0-3 patients each (Table 3).
Table 3: detection rate of prostate cancer lesions, blinded read with cSOT as reference, region level
| N | [18F]PSMA-1007 | Fluorocholine (18F) | Odds Ratio | |||
| [18F]PSMA- | ||||||
| 1007/Fluorocholine | ||||||
| (18F) | ||||||
| (95% CI) | ||||||
Detection rate all regions | 78 | 77.8 % | 59.0 % | 2.43 (1.48-4.00) | ||
| Pelvis | 59 | 82.5 % | 59.3 % | |||
| Spine | 6 | 77.8 % | 61.1 % | |||
5.2 Pharmacokinetic properties
Distribution
[18F]PSMA-1007 distributes immediately following administration via the blood stream. In healthy subjects, the blood pool contained means of 76, 22, 12 and 8 % of the injected activity at 2 minutes, 1 hour, 2 hours and 3 hours after injection, respectively.
Organ Uptake
[18F]PSMA-1007 is preferentially taken up into prostate cancer cells compared with surrounding normal tissues. One hour after injection, tumor lesions become visible and uptake increases up to 3 hours after injection. Median SUVmax in prostate cancer lesions in patients with biochemical recurrence was reported between approx. 4-40.
Highest uptake of [18F]PSMA-1007 into non-target organs was reported for kidneys, salivery glands, lacrimal glands, liver, spleen, gallbladder and pancreas up to 3 h after injection (median SUVmean approx 5-30). Activity in the brain is negligible.
Elimination
The major route of elimination is via the hepatobiliary pathway.
In the study by Giesel et al. (Eur J Nucl Med Mol Imaging. 2017; 44(4):678-688), in 3 healthy volunteers, urinary elimination was minimal and on average 2.4% of the administered radioactivity was eliminated during the 6 hours after injection.
Studies investigating the metabolism of [18F]PSMA-1007 have not been performed.
Half-Life
The effective half-life depends primarily on the short physical half-life of fluorine (18F), which is about 110 minutes, rather than the biological half-life of the carrier molecule.
5.3 Preclinical safety data
Non-clinical data from conventional single dose toxicity studies, safety pharmacology studies and genotoxicity studies did not reveal any particular risk for humans.
6 PHARMACEUTICAL PARTICULARS
6.1 List of excipients
Disodium phosphate
Potassium dihydrogen phosphate
Sodium chloride
Potassium chloride
Sodium ascorbate
Ethanol, anhydrous
Water for Injections
6.2 Incompatibilities
This medicinal product must not be mixed with other medicinal products except those mentioned in section 12.
6.3 Shelf life
12 hours from activity reference time (ART).
After first withdrawal
Chemical and physical stability after first withdrawal has been demonstrated for Radelumin 2000 MBq/mL solution for injection for 12 hours from activity reference time.
From a microbiological point of view, unless the method of dose withdraw/dilution is using aseptic techniques, the product should be used immediately. If not used immediately, in-use storage times and conditions are the responsibility of the user.
After first withdrawal, use before the expiration time.
6.4 Special precautions for storage
Do not store above 30°C.
Storage of radiopharmaceuticals should be in accordance with national regulations on radioactive materials.
6.5 Nature and contents of container
Radelumin is supplied in a 10 mL, 15 mL, or 20 mL type 1 clear glass vials closed with rubber stoppers suitable for multiple piercing and sealed with a cap.
Presentations:
One 10 mL multidose vial contains 0.3 to 10 mL of solution, corresponding to 600-20000 MBq at activity reference time (ART).
One 15 mL multidose vial contains 0.3 to 15 mL of solution, corresponding to 600-30000 MBq at activity reference time (ART).
One 20 mL multidose vial contains 0.3 to 20 mL of solution, corresponding to 600-40000 MBq at activity reference time (ART).
Multidose vial.
Not all pack sizes may be marketed.
6.6 Special precautions for disposal
General warning
Radiopharmaceuticals should be received, used and administered only by authorised persons in designated clinical settings. Their receipt, storage, use, transfer and disposal are subject to the regulations and/or appropriate licences of the competent official organisation.
Radiopharmaceuticals should be prepared in a manner which satisfies both radiation safety and pharmaceutical quality requirements. Appropriate aseptic precautions should be taken.
For instructions on dilution of the medicinal product, see section 12.
If at any time in the preparation of this medicinal product the integrity of the vial is compromised it should not be used.
Administration procedures should be carried out in a way to minimise the risk of contamination of the medicinal product and irradiation of the operator. Adequate shielding is mandatory.
The administration of radiopharmaceuticals creates risk for other persons from external radiation or contamination from spill of urine, vomiting, etc. Radiation protection precautions in accordance with national regulations must therefore be taken.
Any unused medicinal product or waste material should be disposed of in accordance with local requirements.
7 MARKETING AUTHORISATION HOLDER
ABX advanced biochemical compounds Biomedizinische Forschungsreagenzien GmbH
Heinrich-Glaeser-Str. 10-14
01454 Radeberg
Germany
8 MARKETING AUTHORISATION NUMBER(S)
PL 27959/0001
9 DATE OF FIRST AUTHORISATION/RENEWAL OF THE
AUTHORISATION
10 DATE OF REVISION OF THE TEXT
11 DOSIMETRY
The estimated absorbed radiation doses for adult patients following intravenous injection of [18F]PSMA-1007 are shown in Table 4. Values were calculated from human distribution data using OLINDA/EXM (Organ Level Dose Assessment/Exponential Modeling) software version 2.1. The effective dose was calculated according to the organ weighting factors defined in the International Commission on Radiological Protection Publication 103 (ICRP-103).
Table 4: Estimated radiation absorbed doses for prostate cancer patients receiving [18F]PSMA-1007
| Organ | Dose absorbed per activity | ||
| administered (mGy/MBq) | |||
| Brain | 0.0030 | ||
| Eyes | 0.0072 | ||
| Testes | 0.0074 | ||
| Osteogenic cells | 0.0101 | ||
| Muscle | 0.0103 | ||
| Total Body | 0.0103 | ||
| Thymus | 0.0106 | ||
| Red marrow | 0.0121 | ||
| Rectum | 0.0145 | ||
| Lungs | 0.0147 | ||
| Thyroid | 0.0151 | ||
| Stomach | 0.0170 | ||
| Upper colon | 0.0176 | ||
| Esophagus | 0.0187 | ||
| Urinary bladder wall | 0.0212 | ||
| Lower colon | 0.0239 | ||
| Heart wall | 0.0259 | ||
| Small intestine | 0.0334 | ||
| Adrenals | 0.0349 | ||
| Salivary Glands | 0.0642 | ||
| Pancreas | 0.0677 | ||
| Spleen | 0.0851 | ||
| Liver | 0.0883 | ||
| Organ | Dose absorbed per activity | |||
| administered (mGy/MBq) | ||||
| Kidneys | 0.1030 | |||
| Gallbladder wall | 0.1400 | |||
| Effective dose | ||||
| Effective dose (mSv/MBq) (ICRP103) | 0.0191 | |||
The effective dose resulting from the administration of the recommended activity of 280 MBq (for an adult of 70 kg body weight) is about 5.3 mSv.
The effective dose resulting from the administration of the maximum recommended activity of 450 MBq is about 8.6 mSv.
For an administered activity of 280 MBq the typical radiation doses to the critical organs gallbladder, kidneys, and liver are about 39 mGy, 29 mGy, and 25 mGy, respectively.
12 INSTRUCTIONS FOR PREPARATION OF
RADIOPHARMACEUTICALS
Any unused medicinal product or waste material should be disposed of in accordance with local requirements.
Withdrawals should be performed under aseptic conditions. The vials must not be opened. Before any withdrawal, the stopper should be disinfected, the solution should be withdrawn via the stopper using a single dose syringe fitted with suitable protective shielding and a disposable sterile needle or using an authorised automated application system.
If the integrity of this vial is compromised, the product should not be used.
Radelumin may be diluted with sterile sodium chloride 9 mg/mL (0.9%) solution immediately before use.
Quality control
The solution should be inspected visually prior to use. Only clear solutions, free from visible particles should be used.